TECHNICAL DATA
Type Direct Acting
Ambient temperature -10 to +50 °C
Fluid temperature (max) 50 °C
Fluid media Oxygen Gas
Pressure (refer to graph)
Mechanical System Poppet/Armature design with cushioned seals
Ways/Positions 2/2 Normally Closed
Control Power solenoid to open – mechanical spring to close
Connections G1/2 threaded body
Weight 0.25
CONSTRUCTION DATA
Valve Body Brass – nickel plated
Armature/Sleeve
Stainless steel
Retaining locknut
Brass / NBR
Static Seals Viton
Dynamic Seals Viton
ELECTRICAL DATA
Coil Series EB series (coil orientable 360°)
Coil Consumption 11W (DC coils), 17VA (AC coils)
Coil Voltage 24V DC (direct current) 24V, 110V and 240V AC (alternating current)
Coil Winding Class H
Electrical Connector AM-5111
Insulation Rating IP 65
ASSEMBLY DATA
Lubricant material  valve assembled dry, no lubricants used
Sealant material Loctite 577 suitable for CO² service
Cleaning standard Internal parts cleaned in accordance with EIGA standards for CO² (European Industrial Gases Association)
Cleaning method Ultrasonically cleaned, water rinsed and heat dried
Packaging Valves individually bagged, sealed and labelled